The study uses a statistical model to estimate how summaries of PFAS monitoring data change when results below laboratory reporting limits are not treated as zero. Those estimates are not direct measurements of below-limit concentrations and do not establish regulatory compliance or whether any particular result poses a health risk, according to the study in Cell Reports Sustainability.
What a below-limit result means
A minimum reporting level, or MRL, is the threshold below which a laboratory result is not reported as a reliably measurable concentration. A result below that threshold does not show that the compound is absent. In the EPA monitoring data examined by the researchers, 98% of PFAS results were below their MRLs, the study reports.
The analysis used more than 1.8 million PFAS measurements from 9,991 community water systems. The study says the data came from an EPA release in January 2026, representing about 95% of the results the agency expected to collect. For records below reporting limits, the model generated 500 possible concentration values per record rather than assigning zero, according to the study.
What the model estimates
The results are pooled estimates, not readings for individual systems. Across 25 PFAS compounds detected at least once in the monitoring data, the summaries that treated below-limit results as zero amounted to about 44% of the modelled average concentration. For the six PFAS with enforceable federal drinking-water limits, the conventional calculation represented about half of the model estimate.
For those six regulated compounds, the national average calculated by treating below-limit results as zero was about 2.6 nanograms per liter, compared with a model estimate of about 5.2 nanograms per liter. PFOA and PFOS together accounted for 27% to 31% of the study’s Tier A censoring gap, its measure of the difference between measured and modelled concentrations. Re-estimating results by source-water category and system size changed the pooled national estimates by less than 5%, the study reports.
Monitoring and drinking-water limits are separate
The EPA’s Fifth Unregulated Contaminant Monitoring Rule required public water systems to monitor 29 PFAS, as well as lithium, between 2023 and 2025. Separately, the agency’s 2024 National Primary Drinking Water Regulation established enforceable limits for PFOA, PFOS, PFHxS, PFNA, HFPO-DA, also known as GenX Chemicals, and PFBS, according to the Federal Register. The study’s estimates do not change those standards or determine whether a water system complies with them.
A Dallas monitoring snapshot
A City of Dallas memo dated April 26, 2024, said Dallas Water Utilities had completed UCMR5 sampling at its Eastside, Bachman and Elm Fork water treatment plants, according to the City of Dallas. The memo reports detectable UCMR5 PFAS results at its water treatment plants, including nonzero PFOA results at Bachman (3.8 ppt) and Elm Fork (1.0 ppt).
The authors present the modelling as a way to examine how below-limit results affect summaries of monitoring data, not as a substitute for testing. The estimates indicate how different an aggregate calculation may look under another treatment of those results; they do not reveal the actual concentration in any individual sample.